Smart Sense Infrared Thermometer Non Contact

Smart Sense Infrared Thermometer Non Contact

Smart Sense Infrared Thermometer Non Contact The most basic design consists of a lens to focus the infrared (IR) energy on to a detector, which converts the energy to an electrical signal that can be displayed in units of temperature after being compensated for ambient temperature variation....

Smart Sense Infrared Thermometer Non Contact


 product description


The most basic design consists of a lens to focus the infrared (IR) energy on to a detector, which converts the energy to an electrical signal that can be displayed in units of temperature after being compensated for ambient temperature variation. Infrared Thermometers allow users to measure temperature in applications where conventional sensors cannot be employed. Specifically, in cases dealing with moving objects ( i.e., rollers, moving machinery, or a conveyor belt), or where non-contact measurements are required because of contamination or hazardous reasons (such as high voltage), where distances are too great, or where the temperatures to be measured are too high for thermocouples or other contact sensors. 
 

product specification

 

 Temperature range  -50℃~900℃(-58℉~1652℉)
 Accuracy(In the condition of 23°C±3°C) 100℃(212℉) to 600℃(1112℉)±2℃or±2%
 0℃(32℉) to 100℃(212℉) ±2℃or±2%
 -50℃(-58℉)to 0℃(30℉) ±3℃or ±3%
 whichever is greater
 Repeatability 1% of reading or 0.1°C
 Response time   500 mSec, 95% response
 Spectral response     (8-14)um & 500ms 
 Emissivity      0.10 to 1.00 adjustable (pre-set 0.95)
 Ambient operating range      0 to 40°C (32°Fto 104°F)
 Relative humidity     10-95% RH noncondensing 
 Storage temperature      -20 to 60°C (-4°Fto 140°F)
 Weight 170g without battery
 Dimensions  175*100*49mm
 Distance to Spot Size       12:1
 ℃/℉Selection  V
 Data Hold Function V
 Laser Target Pointer Selection V
 Backlight Display Selection V
 Auto Power Off  V
 Power    9v Alkaline or NiCd battery (not inlcude)
Emissivity : Most organic materials and pa-inted or oxidized surfaces have an emissiv-ity of 0.95 (preset in the unit). Inaccurate readings will result from measuring shiny or polished metal surfaces. To compensate, cover the surface to be measured with mas-king tape or flat black paint. Measure the tape or painted surface when the tape or painted reach the same temperature as the material underneath.
 Marterial Emissivity  Marterial Emissivity
 Aluminum 0.30 Iron 0.70
 Asbestos 0.95 Lead 0.50
Asphalt 0.95 Limestone 0.98
 Basalt 0.70 Oil 0.94
 Brass 0.50 Paint 0.93
 Brick 0.90 Paper 0.95
 Carbon 0.85 Plastic 0.95
 Ceramic 0.95 Rubber 0.95
 Concrete 0.95 Sand 0.90
 Copper 0.95 Skin 0.98
 Dirt 0.94 Snow 0.90
 Frozen food 0.90 Steel 0.80
 Hot food 0.93 Textiles 0.94
 Glass(plate) 0.85 Water 0.93
 Ice 0.98             Wood 0.94



Diagram and LCD display:


 

1 Introduction
 Compact, rugged and easy to use. Just aim and push the button, 
 read current surface temperature in less than a second. Safely 
 measure surface temperature of hot, hazardous or hard-to-reach
 objects without contact.                                                                                             

2

  Diagram description
 (1) Trigger: When turn on LCD display VER XX software version for 1 sec.
 And turn to di-splay reading with SCAN icon. Release the trigger,display  reading with HOLD icon for 7 sec. Built in auto power off in 30sec.

 (2) Laser / back light button: when back light turn

 (3)-(6) key functions: 
 press 3 key, LCD subdisplay blinks MAX-MIN-DIF-AVG-HAL-LAL STO
 segment(only main display means normal measuring mode) press 4
 key to enter.
  a. MAX: measuring maximum temperature
  b. MIN: measuring minimum temperature
  c. DIF: Basic on the reading before press 4 key, compute the   

 difference of current reading.
  d. AVG: measuring average temperature
  e. HAL: high temperature alarm--when selected HAL, press 5 keys to set high temperature alarm trigger and confirmed by pressing key.

 When reading over trigger, LCD display HI icon with BiBi audio sounds.
 f. LAL: low temperature alarm--when selected LAL, press 5 keys
 to set low temperature alarm trigger and confirmed by pressing
 4 key. When reading over trigger, LCD display LOW icon with BiBi audio sounds
  g. STO: data storage--when selected STO, lock & DATA & 1--- indicator will shown when press 4 key. After temperature read out press 6 key to store, then 2---memory unit will be shown.
 There 12 groups memory unit available. To recall the stored data  in normal measuring mode by press-ing 6 key, remove all data by pressing 6 keys for 2 secretary.
  h. EMS: Emissivity setup--press 5 keys for emissivity settings, press 4 key to save setup and back to normal status.
 (7) LCD display
 (8) Battery door clip
 (9) Battery door: When replace battery door, please press battery door clip and pull the battery door.
 (10) Clesius / Fahrenheit switch: Please open battery and push the slide switch for con-vertsion Maintenance
 1) Lens cleaning: Blow off lose particles using clean compressed air. Gently brush remaining debris away W/a moist cotton cloth.
 2) Case cleaning: Clean the case with a damp sponge/cloth and mild soap.                                                                        

3

 LCD display:
 A data hold icon
 B scanning icon
 C laser on icon
 D back light on icon
 E battery power icon
 F measuring unit
 G measuring reading

 

4

 Distance & spot size: As the distance from the object increase,
 the spot size of measuring area becomes larger. Field of view:

 Make sure the  target is larger than the unit's spot size. The detected parts diameter  need up to 1.5cm. But the best testing distance is 20cm.when detected parts size is 10*10cm  

 

5 

 Attention:
 1. Red laser point only position the general  direction, the detection

 hole is the main Parts measure the temperature

 2. Do not point laser directly at eye or in-directly off reflective surface.

 

Quick Start Instruction

User's Guide


product show


 

Smart Sense Infrared Thermometer Non Contact

Smart Sense Infrared Thermometer Non Contact



Previous: Handheld Infrared Thermometer GM320 Type 50-380° CIndustrial Non - Contact Infrared Thermometer